Through years of R&D, we perfected a proprietary formulation of Bismuth Telluride as well as other materials, creating semiconductors that dramatically outperform anything that has come before. Our process ensures higher efficiency and long-term stability within our target heat range.

Our Technology

How It Works
At the heart of our technology is a proprietary thermoelectric cartridge. Imagine two plates: one hot, one cold. Our cartridge, built with advanced semiconductor pellets, is sandwiched between them. When industrial waste heat is applied to the hot side, this temperature difference drives a flow of electrons, generating a direct current (DC) of electricity with no moving parts, emissions, or noise.
For decades, this process was too inefficient for commercial use. Our breakthrough is a monumental leap in material science and engineering, achieving 14% normalized thermal efficiency. This 5x improvement over previous attempts for the first time unlocks the vast, untapped energy potential of moderate-temperature waste heat (150-500°C), making its recovery not just possible, but highly profitable.


The Three Breakthroughs (Why Now?)

Advanced Material Science

Automated Manufacturing
Our SSG cartridges are designed to be manufactured at scale on standard Surface Mount Technology (SMT) lines, the same automated processes used to build iPhones. This allows us to scale production globally with contract manufacturers without building custom factories, ensuring rapid and cost-effective deployment.

Industrial Readiness
We designed the entire system for seamless integration into complex industrial environments. The system is containerized, modular, and arrives on-site ready for a simple “drop and connect” installation, minimizing plant disruption and ensuring immediate value.

Solid-State Generator (SSG) Unit Features
- Purpose-Built for Moderate Heat
Our platform is optimized for the 150°C to 500°C range, the most common type of industrial waste heat and a range historically underserved by traditional, high-temperature turbine systems. - Modular by Design
Our containerized units scale from 100kW to multi-megawatt installations, allowing us to tailor a solution to your specific heat source and energy needs. - Ultra-Low Maintenance
With no moving parts, our solid-state system is incredibly reliable, delivering 98% uptime with minimal required maintenance over its 20+ year lifespan. - Fully Secure & Connected
Built on the Schneider EcoStruxure platform, every SSG unit is fully IIoT-enabled, data-rich, and can be monitored and managed from anywhere in the world, even an iPad.
These advances combine to deliver a commercially viable, manufacturable platform ready to address a massive market opportunity today.
Frequently Asked Questions
How does the ATS Energy Solid-State Generator convert waste heat into electricity?
The Solid-State Generator (SSG) uses thermoelectric conduction. Each cartridge sits between a hot plate and a cold plate. When waste heat reaches the hot side, the temperature difference across the semiconductor pellets drives a flow of electrons through the Seebeck effect. That flow produces direct current, and power electronics condition it for use behind the meter. The units are containerized and modular, so a site adds capacity by adding units. Nothing is combusted inside the generator, and no additional fuel is required.
Is the Solid-State Generator a thermoelectric device or a photovoltaic one?
It is thermoelectric. The SSG converts a temperature difference into electricity by conduction through solid semiconductor material. It does not capture infrared radiation, and it is not a photovoltaic or thermophotovoltaic device. The technology is sometimes described as solar-like, and that description is not accurate. The legal entity name, Advanced Thermovoltaic Systems Corp., is a brand choice and does not describe a photovoltaic process.
What are the thermoelectric cartridges made from, and how are they manufactured?
The cartridges use ATS Energy’s proprietary bismuth telluride-based thermoelectric material together with other engineered materials. ATS controls the material formulation, particle characteristics and consolidation process to produce semiconductor material optimized for thermoelectric performance. The material is then processed into pellets and assembled into modular cartridges using scalable manufacturing methods. ATS Energy refers to this integrated materials-to-generator approach as “Powder to Power.”
How does heat from our process reach the SSG?
Through an engineered heat exchanger and a closed thermal loop. The heat exchanger takes energy from the source, such as a kiln stack or a hot liquid stream. A controlled hot loop carries that energy to the generator, and a separate cold loop maintains the temperature difference across the cartridges. The SSG is not mounted inside ductwork or in the gas stream. That separation keeps process gas away from the conversion hardware, which simplifies how the design handles fouling and variable gas composition.
Does the Solid-State Generator have no moving parts?
The conversion core has no moving parts. Electricity is produced by conduction through solid semiconductor material, with no turbine, no expander, and no organic working fluid. The complete system does include moving equipment. Pumps circulate the hot and cold loops, and most sites also need fans or cooling equipment. Those components draw power, and their consumption is accounted for as parasitic load in the net output figure.
What temperature does our heat source need to reach?
There is no single temperature threshold because recoverable power depends on both temperature and available heat flow. As a practical screening guide, ATS Energy’s current commercial systems are best suited to higher-grade industrial heat sources. Hot liquid and process loops generally become attractive at approximately 200°C and above, while exhaust-gas applications typically require higher source temperatures because heat must first transfer through a heat exchanger into the SSG’s controlled thermal loop.
ATS evaluates source temperature, mass flow, allowable outlet temperature, cold-side conditions, annual operating hours and electricity value together. A high-flow stream at a moderate temperature can sometimes provide more usable thermal energy than a much hotter stream with little flow.
What is the difference between gross and net power output?
Gross output is the electricity the thermoelectric cartridges produce. Net output is what the facility actually receives after parasitic loads. Parasitic loads include pumps, fans, cooling equipment, controls, and electrical conversion losses. They vary by site, and an installation that needs a cooling tower carries a higher parasitic load than one with an existing cold water supply. Economic evaluation should always use net output. Confirm which figure an estimate uses before you build a business case on it.
Has the technology been validated by an independent third party?
Yes. ATS Energy participated in the U.S. Department of Energy’s Industrial Technology Validation program, which independently evaluated an ATS waste-heat-to-power system at an industrial facility in Alpena, Michigan. The field validation confirmed that the system generated electricity from recovered heat under operating conditions and measured net electrical performance.
The validation also documented the specific thermal-source and cooling conditions used during the test, which is important because output from any waste heat recovery system depends on the available temperature differential, heat flow and balance-of-plant requirements.
What does ATS Energy’s 14% normalized thermal efficiency mean, and how has this performance been validated?
Yes. ATS Energy participated in the U.S. Department of Energy’s Industrial Technology Validation program, which independently evaluated an ATS waste-heat-to-power system at an industrial facility in Alpena, Michigan. The field validation confirmed that the system generated electricity from recovered heat under operating conditions and measured net electrical performance.
The validation also documented the specific thermal-source and cooling conditions used during the test, which is important because output from any waste heat recovery system depends on the available temperature differential, heat flow and balance-of-plant requirements.
How does the SSG compare with an organic Rankine cycle system?
Both convert moderate-temperature heat into power, and ORC is a proven technology with a long operating record. An ORC unit uses rotating machinery and an organic working fluid, so the scope includes a turbine or expander, fluid management, and the maintenance that rotating equipment carries.
The SSG converts heat with no turbine, no expander, and no working fluid in the conversion core. ORC economics generally improve with scale, so a single large and steady heat stream can favor ORC. The modular design of the SSG suits smaller streams, distributed heat sources, and sites that prefer to add capacity in stages.
The SSG also separates the long-lived thermal and electrical infrastructure from its modular thermoelectric cartridges. As ATS Energy advances its thermoelectric materials and cartridge designs, deployed systems can be upgraded by replacing cartridges rather than replacing the entire generation system. This creates a pathway to increase power output from the same available heat and installed infrastructure over time.
What maintenance does an SSG require?
Maintenance concentrates on the balance of plant rather than the conversion core. The cartridges have no moving parts, no rotating equipment to overhaul, and no working fluid to monitor or replace. Routine attention goes to the pumps, the heat exchanger, the cold loop, filtration, and the controls, on a schedule set during system design. Under the Energy as a Service model, operation and maintenance sit with ATS Energy instead of with your team.

Stop Venting Profits
Start Generating Them
A proven team, a protected technology, and powerful market tailwinds have converged to create a singular opportunity to lead a paradigm shift in industrial energy. Our leadership is ready to execute on this vision.